Skip to content

Taidacent Timer Switch Circuit High Power 30A Delay Time Relay to Control Water Pump 7-27V DC 220V AC Relay Switch

$7.88


Price: 7.88

Parameter

1: Product model: 24 commonly used functions to meet more needs;
2: Input voltage: DC 5/12/24 / 220V optional
3: Output power: can control DC or AC load within 30A
4: Time range: 0.01 seconds ~ 999 minutes
5: Application: Can control the operation of solenoid valves, pumps, motors, lights, etc.

Wiring port description

1. DC +: Input positive pole of DC power supply (L: input AC power line)
2. DC-: negative pole of input DC power supply (N: input neutral line of AC power supply)
3, NO: relay normally open interface, the relay is suspended before pull-in, short-circuited to COM after pull-in
4. COM: Relay common interface
5. NC: Normally closed interface of relay, short-circuited to COM before pull-in, left floating after pull-in

Function

The function can be set back when you buy it; any parameter can be memorized when power is off
“Give Signal” in the list: it can be the “Start / Stop” button on our panel, or it can be triggered externally
P-11: Jog (pull on the signal relay, the signal disappears and the relay stops)
P-12: Self-locking (pull on the signal relay once and stop it again)
P-13: give a signal, the relay will automatically stop for A second after closing; the trigger is invalid during the delay time
P-14: Give the signal, the relay will automatically stop for A second after the pickup; trigger re-timing during the delay time
P-15: Give the signal, the relay will automatically stop for A second after the pickup; trigger the overlay timing during the delay time
P-16: give a signal, the relay will automatically stop for A second after the pickup; trigger reset during the delay time
P-17: Give the signal, the relay pulls in, the input signal is disconnected, the power is turned off A seconds after the start of the timing, the signal is kept output again during the delay period, and the timing stops
P-18: After the power is turned on, the relay will immediately pull in and power off after a delay of A seconds; until the next power on
P-21: Give the signal, after the delay of A seconds, the relay will pull in
P-22: Give the signal. After more than A seconds, the relay pulls in, the signal disappears, and the relay stops.
P-23: After the signal disappears for more than A second, the relay is closed, the signal disappears, and the relay stops.
P-24: When the signal is over A seconds, the relay is closed. When the signal disappears over A seconds, the relay is stopped.
P-25: When the signal exceeds A seconds, the relay is closed. When the signal exceeds A seconds, the relay stops.
P-26: With signal, the relay stops after A second, and the signal disappears. The relay stops after A second.
P-27: Detection of pulse signal, the relay stops; without pulse signal, the relay delays for A second to pull in; (the signal continues or the signal disappears, it is regarded as no pulse signal)
P-28: After power-on, after a delay of A seconds, the relay will close until power is off
P-31: After energizing, the relay will pull in for A seconds, disconnect for B seconds, infinite cycle; stop after power off
P-32: With signal, start P-31 infinite loop; signal disappears, terminate loop
P-33: Give the signal once to start the infinite loop of P-31; Give the signal again to terminate the loop
P-34: After power on, the relay will pull in after A seconds, and stop after B seconds.
P-35: There is a signal. After a delay of A seconds, the relay will pull in and stop after B seconds.
P-36: There is a signal. After more than A seconds, the relay will pull in and stop after B seconds. The signal will disappear and the timing will be cleared and stopped.
P-37: If there is a signal, the relay will automatically stop for A second after the pickup. After the stop, it will count for B seconds. The signal trigger is invalid in A + B time.
P-38: After the signal is given more than A times, the relay will stop for B seconds.

Key setting instructions

Power-on display “————” means entering standby state;
Press “Set” for the first time, (it takes more than 1 second to be effective to prevent false triggering)
Display: P -11: “+” “-” “Start / Stop” adjustment function mode
Press “Set” a second time, the screen displays: A001: “+” “-” “Start / Stop” adjust the first time A
Press “Set” a third time, the screen displays: B001: “+” “-” “Start / Stop” adjust the second time B
Press the “Setting” for the fourth time, “————” is displayed to indicate standby
“Start / Stop” in standby mode as start / stop signal for all functions

Decimal point time unit description

X.XX decimal point is in hundreds place, timing range: 0.01 second to 9.99 second
XX.X decimal point is in ten digits, timing range: 0.1 second to 99.9 second
XXX has no decimal point, timing range: 1 second to 999 seconds
XXX. Decimal point is in single digits. Timing range: 1 minute ~ 999 minutes

Reviews

There are no reviews yet.

Be the first to review “Taidacent Timer Switch Circuit High Power 30A Delay Time Relay to Control Water Pump 7-27V DC 220V AC Relay Switch”

Your email address will not be published. Required fields are marked *